There are 3 types of count conversion system. Such as:-
1. Direct to direct
2. Indirect to indirect
3. Indirect to direct or direct to indirect.
Conversion from one system two another is achieved by converting factors and constant. Where a direct to direct or indirect to indirect system conversion is done, a multiplying factor is used. This multiplying factor is multiplied by the known count and thus the required count can be obtained.
Direct to direct system conversion:
Let,
Nr= Count in required system
Nk= Count in known system
Wk= Weight unit in known system
Wr= Weight unit inrequired system
Lk= Length unit in known systembr
Lr=Length unit in required system
Then,
Nr= Nk × |
(Wk/Wr)
(Lk/Lr)
|
Or, Nr= Nk × |
(Wk×Lr)
(Wr×Lk)
|
(multiplying factor) |
Example, Tex = denier × 0.111 (0.111 is the multiplying factor)
Or, Denier = 9 × Tex (9 is the multiplying factor)
Indirect to indirect system conversion:
Let,
Nr= Count in required system
Nk= Count in known system
Wk= Weight unit in known system
Wr= Weight unit inrequired system
Lk= Length unit in known systembr
Lr=Length unit in required system
Then,
Nr= Nk × |
(Lk/Lr)
(Wk/Wr)
|
Or, Nr= Nk × |
(Wr×Lk)
(Wk×Lr)
|
(multiplying factor) |
Example:
Cotton count × 1.5 = Worsted count
Or, Worsted count = Cotton count × 1.5
Here, 1.5 is the multiplying factor.
Direct to indirect system conversion:
Let,
Nr= Count in required system
Nk= Count in known system
Wk= Weight unit in known system
Wr= Weight unit inrequired system
Lk= Length unit in known systembr
Lr=Length unit in required system
Then,
Nr= |
1
Nk
|
× |
(Lk/Lr)
(Wk/Wr)
|
Or, Nr= |
1
Nk
|
× |
(Wr×Lk)
(Wk×Lr)
|
(multiplying factor) |
Example:
Denier = (7972/Worsted Count)
Or, Denier = (A constant of conversion/Worsted Count)
Here, 7972 is the multiplying factor.
Indirect to direct system conversion:
Let,
Nr= Count in required system
Nk= Count in known system
Wk= Weight unit in known system
Wr= Weight unit inrequired system
Lk= Length unit in known systembr
Lr=Length unit in required system
Then,
Nr= |
1
Nk
|
× |
(Wk/Wr)
(Lk/Lr)
|
Or, Nr= |
1
Nk
|
× |
(Wk×Lr
(Wr×Lk))
|
(multiplying factor) |
Example:
Cotton Count = (A Constant/Denier)
Or, Cotton Count = (5315/Denier)
Here, 5315 is the multiplying factor.
By using below table, count can be converted easily.
No comments: